Step 6
Electrical
The Bosch dryer comes with 4-wire power supply cord
pre-installed. This cord fits a 4-wire receptacle as shown
in the upper section of Figure 11.
If your receptacle is a 3-wire receptacle, as shown in the
lower section of Figure 1, a 3-wire ''Dryer Cord'' must be
purchased locally. The 4-wire cord must then be
removed and the 3-wire cord installed in its place.
Electrical Connection, 4-Wire
For a 4-wire system, all that is necessary is to plug
the 4-wire power supply cord into the 4-wire receptacle
of the proper rating.
Note: The receptacle should be located so that the plug
and receptacle will be accessible when the dryer
is in its final installed position.
Electrical Connection, 3-Wire
If your receptacle is a 3-wire receptacle as shown below,
Figure 19, you must obtain a 3-wire dryer cord. Dryer
cord can usually be found at your local hardware supply,
electrical supply or home center. Cord should have
closed loop or upturned end wire terminating connectors.
3-wire receptacle
Typical 3-wire Dryer Cord
240V/30 amp NEMA 10-30 Type SRDT
Figure 19.
Note: If the dryer is installed in a mobile home or in
areas where local codes do not permit grounding,
only a 4-wire power supply cord shall be used.
(10-30R)
To Change Cord:
1. Make sure that the dryer is not plugged into any
power outlet.
d
DO NOT plug end of dryer power cord into a live
receptacle before connecting dryer power cord to
dryer terminals and closing junction/splitter box as
described below.
DO NOT reuse old power supply cord.
Power cord must be changed only by a qualified
person.
2. Remove the screw from the cover of the
junction/splitter box located at the top rear
of the dryer.
3. Remove the green ground wire from the ground
terminal.
4. Remove the red, white and black wire from the
terminal block.
5. Loosen the 2 screws in the U.L. strain relief clamp,
holding the 4-wire cable.
6. Thread the 4-wire cable out through the U.L. strain
relief clamp and throw away.
7. Thread the new 3-wire dryer cord through the U.L.
strain relief clamp.
8. Attach the power cord Ground conductor (the center
wire) to the Ground terminal. Tighten the terminal so
that it securely holds the Ground conductor.
9. Attach the two remaining power cord outer
conductors to the 2 terminals labeled L. Tighten both
screws so that the power conductors are securely
held in place. See Figure 20.
10. Tighten the screws on the U.L. strain relief so that
the power cord cannot be moved.
WARNING