Maintenance:

Battery Replacement:
The Batteries for the LeakTrac 2400 should be replaced whenever the LOW BAT
Indicator light is illuminated, or as a first step in problem solving if the unit is not
working properly.
The Signal Processing Unit requires two AA batteries that are replaced by remov-
ing the plastic cover on the back of the unit. The Power Booster requires 8AA
batteries that are replaced by removing the brass knobs and bottom panel of the
unit.
Regular Maintenance:
The brass plate on the Input Float may build up some corrosion over time.
Regularly clean the plate with steel wool to keep it conductive.
Care:
As with any electrical equipment, moisture will cause corrosion problems. Do
what you can to keep the equipment and the inside of the case dry. When used
regularly, leave the case open at night to allow all the components to dry out.
Safety:
Because a small electrical charge is being placed in the pool water there is a risk
of minor electrical shocks being felt if you become a connection from the pool wa-
ter to ground. This shock should not be harmful to persons with out medical con-
ditions. However, several safety rules should be followed as a precaution:
- Never contact both the pool water and the ground while the LeakTrac
2400 is turned on
- Always wear rubber soled shoes when using the LeakTrac 2400
- Never allow swimmers in the pool while the LeakTrac 2400 is turned on
2885 Country Drive #190 · St. Paul, MN 55117 · 800-348-1316 · www.leaktools.com
16