Electrolux CH 910 Руководство пользователя - Страница 24
Просмотреть онлайн или скачать pdf Руководство пользователя для Вентиляционная вытяжка Electrolux CH 910. Electrolux CH 910 28 страниц. Stylish stainless steel chimney hood
Также для Electrolux CH 910: Книга инструкций (21 страниц)
24 electrolux
Electrical Connection and Working
Test
Before fi tting the chimney to the
canopy make the electrical connection
as described in the section titled
EN
"ELECTRICAL CONNECTION".
When the electrical connection has been
made, test the three speed fan and
worktop illumination.
Fitting the Chimney Stack
The chimney consists of two sections.
The lower chimney measures 740mm and
the upper chimney (with the recirculation
grilles on either side) measures 465mm.
The overall installed measurement is min.
870 - max 1200mm.
Upper Chimney
To fi t the upper chimney section item 2.1
expand the chimney slightly to allow it to
be fi tted over the brackets item 7.2.1 as
illustrated.
When installed in the recirculation mode
ensure that the recirculation ducting
outlet extension pieces item 14.1 align
correctly with the outlet grilles in the
chimney.
Secure the sides of the chimney to the
brackets using the four screws item 12c
(2.9x9.5mm) provided, as illustrated.
Lower Chimney
To fi t the lower chimney section item 2.2
expand the chimney slightly to allow it to
be fi tted over the upper chimney item 2.1
and the hood body item 1 as illustrated.
Secure the sides of the chimney to
the hood body using the two screws
item 12c (2.9x9.5mm) provided, as
illustrated.
INSTALLING THE COOKER HOOD