OPERATING THE DRAGON
Breathing Hazard
Fuel exhaust contains deadly carbon monoxide gas.
Operate Dragon only outdoors in open area. NEVER
operate indoors or in enclosed spaces.
Electric Shock Hazard
Unit must be grounded. Use only with 3-hole grounded
outlet.
Never modify plug or use an adaptor. If an extension
cord is needed, it must have a three-prong grounding
plug, be rated for outdoor use and be rated for at least
506 watts or 4.4 amps @ 115 volts.
Never operate the Dragon in pooled or standing water. If
electrical components become wet, allow to dry before
using.
Fire and Explosion Hazard
Burner produces sparks and flame and unit becomes hot
during use.
Keep away from flammable vapors, such as those from
gasoline, paint thinner or solvents.
Keep away from combustible dusts, such as coal dust or
sawdust.
Keep unit at least ten feet away from any combustible
material.
Keep children and pets away.
Diesel fuel is flammable and can be explosive.
Do not smoke while operating, servicing, or refueling
the Dragon.
Before refueling, shut off unit, allow to cool and then
unplug.
Hot surfaces can ignite fuel vapors.
Setting up the Dragon
Choosing a location
Use the Dragon outdoors only. Place the unit on a level,
stable surface. Choose an inconspicuous location away
from high-traffic areas for children and/or pets. Ensure
there is no obstruction in the air intake during the use of
the Dragon.
NOTICE: Keep air intake vents under unit clean and
clear of any obstruction. Avoid setting up unit where the
intake could be blocked or restricted i.e. tall grass, deep
07-00407 E 08/2006
Copyright 2006 Dri-Eaz Products, Inc.
snow, etc. Blocking the air intake will cause the unit to
burn inefficiently resulting in sooty exhaust and potential
damage to the unit and the structure being heated.
Air Intake vents shown from underneath unit.
Connecting the internal tank fuel lines
To connect the fuel lines, simply push the male and
female adapters together until the lock rings snap
into place. Note that the adapters are arranged so
that you will always connect the lines properly. You
must always connect both fuel lines.
Connect the internal tank fuel lines
The Dragon is shipped with the fuel lines disconnected.
Before operating, make sure the fuel lines from the
internal tank are properly connected.
You may also operate the Dragon with an external fuel
tank (not included). See the section "Connecting an
external fuel tank" for more information.
Fill the internal fuel tank
The Dragon is shipped with an empty fuel tank. Before
operating, fill the internal tank with diesel #2 fuel oil only.
The internal tank has a 9.3-gallon capacity. Do not
overfill.
3