Electrolux Vent Hood Руководство по эксплуатации и уходу Инструкции по установке - Страница 8

Просмотреть онлайн или скачать pdf Руководство по эксплуатации и уходу Инструкции по установке для Вентиляционная вытяжка Electrolux Vent Hood. Electrolux Vent Hood 16 страниц.

8
Installation

Prepare the hood

NOTE
On stainless steel hoods, carefully remove the
plastic protective film from all exterior surfaces
of the hood and decorative flues, prior to final
installation.
Fix the electrical mounting plate with (2) 3.9x9.5mm
screws and (2) serrated washers. Fig. 3.
ELECTRICAL MOUNTING
PLATE
DUCTED CONFIGURATION
Mount the discharge collar above the hood. Fig. 4.
NON- DUCTED CONFIGURATION
NOTE
Purchase a Non-ducted recirculation KIT from
your dealer (Model DFKTPC40EC).
1. Insert the non-ducted recirculation plenum through
the support frame openings. Fig. 5.
2. Through the support frame openings fit the duct
connector to the plenum locking it with a turning
movement. Fig. 6.
3. Fix a 5" duct to the duct connector of the non-ducted
recirculation plenum. Fig.6.
4. Mount the 6"/5" adapter above hood. Fig. 7.
MOUNTING
SCREWS
(3.9x9.5mm)
FIG. 3
5" DUCT
DISCHARGE
COLLAR
FIG. 4
NON-DUCTED
RECIRCULATION PLENUM
FRONT
DUCT
CONNECTOR
6"/5"
ADAPTER
FIG. 5
FIG. 6
FIG. 7