Electrolux WRH908I Series Руководство пользователя - Страница 7
Просмотреть онлайн или скачать pdf Руководство пользователя для Вентиляционная вытяжка Electrolux WRH908I Series. Electrolux WRH908I Series 12 страниц. Retractable
Также для Electrolux WRH908I Series: Руководство по эксплуатации/инструкция по установке (12 страниц), Руководство по эксплуатации и установке (12 страниц)
OPERATION
IMPORTANT!
The Edison Screw lamps may have come loose
during transportation.
Ensure that lamps are tightened firmly into the
socket before power is applied.
REHR6*
The operation of the light and the two-speed fan are
controlled by the drawer action. (see diagram)
WRH605I* WRH608I* WRR614*A WRH908I*
The operation of the lights and the three speed fans
are controlled by the drawer action. (see diagram)
Fan speed
3 speed
models
2 speed
models
To replace the light globes
1. Open drawer and remove filter.
2. Turn mains switch off before removing lamp.
Replace with 28W maximum E14 halogen candle lamp.
Depending on model will require 1 or 2 globes. The lamp
assembly includes a silicone seal, this must be replaced
when a new lamp is used. The silicone seal is placed over
the lamp thread and then the lamp is screwed into the
holder. Ensure replacement lamp is tightened firmly.
Replacement lamps from Electrolux Parts Centres are
supplied with silicone seals.
Maintenance
To maintain efficiency and reduce fi re risk, fi lters should
be removed every four weeks (maximum) for cleaning.
Soak and agitate filters in hot soapy water or washing
soda. Rinse, drain, shake well and replace.
Do not use caustic solutions or other corrosive agents.
The filters can be washed in the dishwasher,
recommended the filters be placed on the top shelf of
the dishwasher.
NOTE: Where fitted, optional carbon filters are intended
to be a disposable item and should be discarded
when saturated. Washing the carbon filter is not
recommended.
Remove filters for cleaning
1. Slide filter tray forward 1cm.
2. Push in clip on either side to release fi lter. Fig 1.
3. Pull filter downwards to remove. Repeat 2 & 3 for
models with a second fi lter. Fig 2.
4. Turn off mains switch before cleaning drawer and
rangehood body.
5. After cleaning, re-fit filters making sure the clip pins
are securely fitted into the locating holes in the
rangehood body and for twin filter versions, also
located in the pull out drawer section.
6. Holding clip in, push opposite side of filter up until pins
are over locating holes.
7. Release clip ensuring fi lter is securely fitted.
Safety Tips: Use of two hands for removal and re-fitting
of filters is recommended to avoid accidental dropping
of filters which could cause damage to your cooktop or
kitchen surfaces.
Press
Fig. 1
Fig. 2
7