Daikin ATM18MV2S Руководство по эксплуатации - Страница 17
Просмотреть онлайн или скачать pdf Руководство по эксплуатации для Воздухораспределители Daikin ATM18MV2S. Daikin ATM18MV2S 20 страниц. Removal procedure, 5.0/6.0/7.1 kw class, 15000/18000 btu/h class
Также для Daikin ATM18MV2S: Руководство по эксплуатации (20 страниц)
Si041254EE
10.Fan Motor / Fan Rotor
Warning
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Step
1
Remove the 2 screws.
2
Lift and remove the
right side plate.
3
Remove the screw, and
then the fan motor
fixing plate.
4
Loosen the screw of the
fan rotor.
5
Remove the fan motor.
Removal Procedure
All manuals and user guides at all-guides.com
Procedure
Fan rotor
You can remove the fan
rotor without detaching the
right side plate.
Right
side
plate
(R16544)
When reassembling the fan
motor and the fan rotor,
provide as much as 5 mm
(0.2 inch) of play between
the side face of the rotor and
the bottom frame.
Fan motor fixing plate
Side face of rotor
(R2805)
(R2806)
(1) Insert the fan motor allowing
for approx. 5 mm (0.2 inch)
of play.
(2) Tighten the fan rotor screw
until it stops. Then give the
screw one more turn.
(3) If the fan rotor rotates
appropriately, tighten the
screw completely.
Fan motor
(4) If not, repeat the procedure
from (1).
(R12897)
Fan Motor / Fan Rotor
Points
Side face of
bottom frame
5 mm (0.2 inch)
(R18879)
(R9582)
15