Daikin ATM18MV2S Servis Kılavuzu - Sayfa 17

Hava Kontrol Cihazları Daikin ATM18MV2S için çevrimiçi göz atın veya pdf Servis Kılavuzu indirin. Daikin ATM18MV2S 20 sayfaları. Removal procedure, 5.0/6.0/7.1 kw class, 15000/18000 btu/h class
Ayrıca Daikin ATM18MV2S için: Servis Kılavuzu (20 sayfalar)

Daikin ATM18MV2S Servis Kılavuzu
Si041254EE

10.Fan Motor / Fan Rotor

Warning
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Step
1
Remove the 2 screws.
2
Lift and remove the
right side plate.
3
Remove the screw, and
then the fan motor
fixing plate.
4
Loosen the screw of the
fan rotor.
5
Remove the fan motor.
Removal Procedure
All manuals and user guides at all-guides.com
Procedure
Fan rotor
You can remove the fan
rotor without detaching the
right side plate.
Right
side
plate
(R16544)
When reassembling the fan
motor and the fan rotor,
provide as much as 5 mm
(0.2 inch) of play between
the side face of the rotor and
the bottom frame.
Fan motor fixing plate
Side face of rotor
(R2805)
(R2806)
(1) Insert the fan motor allowing
for approx. 5 mm (0.2 inch)
of play.
(2) Tighten the fan rotor screw
until it stops. Then give the
screw one more turn.
(3) If the fan rotor rotates
appropriately, tighten the
screw completely.
Fan motor
(4) If not, repeat the procedure
from (1).
(R12897)
Fan Motor / Fan Rotor
Points
Side face of
bottom frame
5 mm (0.2 inch)
(R18879)
(R9582)
15