Installation and connection:

To protect the user against electric shock, it is important that the hand dryer is connected to the earth wire.
For fixed installation, connect via circuit breaker.
1. Remove the two cover screws at the bottom
of the cover using the supplied special Allen
key. Carefully remove the housing from the
base plate.
Remove the
cover screws
2. Attach the base plate to the wall using ap-
propriate screws in the four mounting holes.
Wiring can be hidden behind the machine or
may alternatively be fed through the bottom
of the cover.
Hole for wall
mounting
screw
Hole for wall
mounting
Cut-out
screw
for wiring
through the
bottom
DAN DRYER A/S • Alsikevej 8 • DK-8920 Randers NV • www.dandryer.com • [email protected]
Document
3000 DAN DRYER Hand dryer.
Maintenance and service manual
3. Do not mount directly above sink or the like.
4. Connect wires as follows:
Hole for wall
mounting
5. Remount the cover using the two cover
screw
Hole for hidden
wiring
Hole for wall
mounting
screw
Lang.
UK
Minimum distance 300 mm.
A. Connect the live wire (red or brown) to the
terminal block marked "L".
B. Connect the neutral wire (blue or black) to
the terminal block marked "N".
C. Connect the green and yellow earth wire to
the screw marked "
".
screws at the bottom of the cover and test
run the hand dryer.
Page