Flush Boost
If the ush test carried out in Section 3 failed on either or both ush options
a Boost can be independently applied to deliver more air to the valve.
Step 1
Press any rear button once to enter Boost Mode.
The current boost setting will now be displayed for both full and partial ush.
Step 2
Toggle Boost ON and OFF for full and partial
ush using the rear buttons.
Step 3
To store Boost settings wait 5 seconds until
the icons return to blue.
O R
5
Fill Delay
This sets the delay period between consecutive ushes to allow the cistern to
rell. This can be set at a range of time periods between 15 and 120 seconds
which are visible on the ll delay dial.
Step 1
Measure the ll time after several
full ushes and record an average.
Step 2
Using a at-ended screwdriver
rotate the ll delay dial to a
duration suitable to the time
previously recorded.
FULL
ON
OFF
PARTIAL