8

Manual settings

To enter the manual settings (virtual dip-switches)
proceed as follows:
1. With the control panel disarmed, press the
PRT button (12) for 3 seconds to enter the
settings
2. The control panel emits 3 beeps and positions
itself on the first function indicated by the
flashing LED (1)
3. The LED ring (6) indicates the setting of the
selected function with a different color
GREEN = function enabled
RED = function disabled
4. To change the function setting, briefly press
the central button (5)
5. To advance to the next function, briefly press
the PRT button (12) and the next LED will flash
Function
Description
Enabled (GREEN LED)
access with APP requires only
the username, without
Function 1
password.
INSTALLER access is always
Led 1
enabled.
Disabled (RED LED)
Web access
access with APP requires both
without
username and password.
password
INSTALLER access is enabled
and disabled by an
Administrator user.
Enabled (GREEN LED)
The Wi-Fi is set in Access Point
mode, i.e. it is possible to
connect with a PC, tablet or
phone directly to the Wi-Fi
integrated in the control panel.
The control panel automatically
Function 2
assigns an IP to the device that
connects in DHCP.
Led 2
Wi-Fi name = EzyLan_<serial>
Wi-Fi Access
Password = 12345678
Point Mode
Security = WPA2 / WPA1 / PSK
Disabled (RED LED)
The Wi-Fi is set to connect to a
Wi-Fi router. The parameters
for the connection must be set
by software.
6. To exit the settings and save the changes,
press and hold the PRT button (12) until a long
beep is heard.
7. To exit the settings without saving the
changes, do not press any button for 10 sec,
the control panel will automatically exit the
settings with a long beep.
9
Programming of the control panel
The control panel can be programmed only using
the dedicated application "DUEVI Connect",
available for Windows, IOS and Android systems.
Once the software has been installed on the
device used for programming:
update graphical interfaces
add the control panel with local search or via
QRCODE
The panel, resetted at factory conditions, only can
be programmed through one of the following
network connections:
connection via direct cable Ethernet
connection via Ethernet local network
direct Wi-Fi connection in Access Point mode
Access Point factory settings:
Name= EzyLan_<serial>
Password= 12345678
10 Homepage (INFO)
Access the control panel as USER INSTALLER
User name = installer
Password = admin (by default is disabled)
As soon as you log in, the main screen
(homepage) will open, which displays a series of
information about the control panel:
System – Summary of the main programmed
elements
Connections – Indication of the status of the
various connections. By pressing the icon
(info), more details are displayed
Power – Indications on the power supply and
battery of the control panel
The homepage also contains two buttons:
ENTER SETUP – Allows to enter the setup
mode (programming) of all the parameters of
the control panel. In setup mode the control
panel is not operational and does not accept
commands from the user.
ENTER TEST – Allows to enter system test
mode. In test mode the control unit is not
operational and does not accept commands
from the user.
From any page, you can return to the homepage
by pressing the icon
FIRMWARE UPDATE: Before starting
programming it is advisable to check if a
Firmware update is available [see section
"Devices (SETUP)"]
(house).