Cascade 90FX Инструкция по установке - Страница 9

Просмотреть онлайн или скачать pdf Инструкция по установке для Вилочные погрузчики Cascade 90FX. Cascade 90FX 14 страниц. Swing frame paper roll clamp

I
NSTALLATION
3
Prepare Hoses or Install Hose Kits
A
Position truck carriage behind roll clamp.
B
Determine hose lengths required.
C
Cut hoses to length, install end fittings and
connect hoses to truck supply terminals for
flushing.
CAUTION: Hoses should be 2300 psi working-
pressure rated for all attachment functions.
No. 8 hose is recommended for all functions.
NOTE: Revolving Connection end block may have either
LH or RH porting for the CLAMP and ROTATE/SWING
circuits (LH CLAMP circuits shown in following illustrations).
INSTALLATION USING RH 2-PORT
THINLINE
HOSE REEL AND SINGLE
INTERNAL HOSE REEVING:
Clamp
Flush hydraulic supply hoses
4
A
Connect hoses together using union fittings
as shown.
B
Operate auxiliary valves for 30 sec.
C
Remove union fittings.
D
IMPORTANT: Disconnect hoses from
supply terminals and connect to roll clamp
revolving connection end block fittings as
shown in Step 3 above.
6028021 Rev. 1
Rotate CW/
Open
Swing Retract
Rotate CCW/
Swing Extend
INSTALLATION USING RH & LH 2-PORT
THINLINE
INSTALLATION USING DOUBLE INTERNAL
HOSE REEVING:
Clamp
RC0923.ill
HOSE REELS:
Revolving
Connection
End Block
Rotate CW/
Swing Retract
Open
Clamp
Rotate CCW/
Swing Extend
Rotate CW/
Open
Swing Retract
RC0947.ill
RC0945.ill
Rotate CCW/
Swing Extend
RC0924 .ill
7