12. Fully open the house main water shutoff valve; Observe a steady flow from
both faucets opened earlier
13. Slowly, turn bypass valve back in the service position; keep soft water
faucets open
14. After about 3 minutes, open a HOT water faucet for one (1) minute,
or until all air is expelled, then close
- NOTE: If water appears cloudy or has a salty taste, allow it to run
for several more minutes, or until clear
15. Close all water faucets
16. Check plumbing work for leaks and fix immediately if any are found
17. Turn on the gas or electric supply to the water heater
18. Connect electrical power by plugging the transformer into a (120 volt) outlet
19. With the valve "In Service", manually initiate a backwash as the final
installation step. This backwash will:
- Complete the final flushing and conditioning of the EcoPur S-Series
ECOPUR S-SERIES CONTROL OPERATION AND SETTINGS
7