Slide cable gland parts toward the gland with the help of the metal nut. Note, that the plastic tightening part
has assembly direction tabs to fit correctly to the metal body. Tabs are shown with the red arrow in the
picture below.
Tighten the nut with the help of the suitable feeler gauge, which thickness depends on used interface cable.
For standard IPEX cable the thickness of the feeler gauge is 2mm. Make sure, that feeler gauge is
removable after tightening the nut. Note! It is not allowed to loose the nut at all after tightening it!
Prior to the tightening of the nut, use the
threadlocker in the thread of the cable gland to
secure the assembly. Suitable threadlocker type
is medium strength type, like Würth 0893243050
or equivalent.
11