Dropping below the threshold value for twilight/night.
Night closure is executed.
Indoor and outdoor temperature:
Indoor temperature is OK. Shading is released.
If the not symbol is displayed, the indoor temperature block is active.
Outdoor temperature is OK. Shading is released.
If the not symbol is displayed, the outdoor temperature block is active.
Retraction delay is running. Shading is blocked because indoor temperature is
too low.
Sun direction:
The sun is in the shading zone (compass direction). Shading is released.
Sun protection function:
Brightness threshold value for shading has been exceeded, extension delay is
running. After the delay time has expired the shading is extended, if all other
conditions are OK.
Brightness threshold value for shading has been exceeded.
Shading is performed if all other conditions are OK.
Brightness below threshold value for shading, retraction delay is running.
Shading is retracted after the delay time has expired.
Brightness below threshold value for shading.
Sun protection automatic inactive.
Window
Please note that for an action such as "Ventilate according to indoor temperature" a
number of conditions must be fulfilled. The functions are listed here in the sequence
of their priority. This means that the temperature-dependent ventilation function is
only executed if all previously named functions for the ventilation have been released.
The detailed description of the automatic functions can be found in the Windows-Ven-
tilation-Automatic mode chapter in the manual.
Alarm functions:
Alarm functions have the highest priority and prevent manual operation of the output.
Wind alarm. Window closed.
Manual mode: Manual operation blocked. Automatic mode: Output can be oper-
ated if the wind automatic block is running.
Frost alarm (combination of precipitation and low outdoor temperature).
Window closed.
Solexa II Control • above Software-Version 1.5 • Version: 07.06.2016
Technical changes and errors excepted.
9
Operating the display