Safety / Operation
J
Do not place the charging station driectly on or
next to the battery!
J
After completing the charging and floating charge
operation on a battery permanently installed in
the vehicle, first disconnect the cable of the
negative (minus) pole (black) of the charger
from the negative (minus) pole of the battery.
J
In case of malfunction or damage, immediately
disconnect the charging station from the mains!
J
Have the charging station repaired by authorised
and trained specialists only! Please contact the
service department for your country!
J
Before connecting the charging station, read
the information on battery maintenance in the
operating instructions of the battery!
J
Before connecting the charging station to a bat-
tery permanently installed in a vehicle, read the
information on electrical safety and maintenance
in the operating instuctions of the vehicle!
J
Disconnect the charger from the mains current
and the battery when not in use!

Properties

This device is designed for the charging of a variety
of SLA batteries (sealed lead-acid batteries), which
are used in motorbikes and some other vehicles,
such as WET (with liquid electrolyte), GEL (with gel
electrolyte) or AGM batteries (with electrolyte-absorb-
ing mats). Their capacity ranges from 12 V / 1.2 Ah
to 12 V / 20 Ah.
A special design feature of the device permits the
battery to be re-charged to nearly 100% of its capacity.
Furthermore, a long-term connection of the battery
to the charging station can take place to keep the
battery in optimal condition when not in use, without
it being damaged in the process.

Operation

Connection

j
Clamp the "+"-pole (red) Y of the charger to
the "+"-pole of the battery.
14 GB
j
Clamp the "–"-pole (black) U of the charger
to the "–"-pole of the battery.
j
Connect the power cable T to the mains current.
Charging function
·
The charging process starts up and the device
automatically recognises the voltage.
·
If the battery voltage is ≤ 7.5 ± 0.25 V, the
device stops charging and the green LED light
"Charging" W flashes. In this case, the battery
can no longer be charged.
·
If the battery voltage is ≥ 7.5 ± 0.25 V, the device
starts the fast charge mode with an amperage of
0.75 A ± 10% and the red LED light "Charging" W
lights up. If the battery has been fully charged
to 14.4 ± 0.25 V, the device switches over to
the fully charged mode. The green LED light
"Charging" W lights up and the battery is now
charged with just a fraction of the amperage.
·
If the battery is still in charging mode and the
device ascertains that the charge has gone down
to 13 ± 0.25 V, it returns to fast charge mode.
Subsequently the battery is charged with just a
fraction of the amperage until the charge has
been reduced to 13 ± 0.25 V. This prevents the
battery from being overcharged.
Protective function
·
If the battery output has reversed the polarity
protection in the charging mode, the red LED
"Error" E lights up and the charger switches off.
·
If the output terminal short-circuits, the charger
will not emit any power.
Disconnecting
j
Disconnect the device from the mains current.
j
Remove the "–"-pole (black) U of the charger
from the "–"-pole of the battery.
j
Remove the "+"-pole (red) Y of the charger
from the "+"-pole of the battery.