4O3A Rotator Genius Руководство - Страница 5

Просмотреть онлайн или скачать pdf Руководство для Контроллер 4O3A Rotator Genius. 4O3A Rotator Genius 20 страниц.

Use
button to navigate to next item.
OFFSET R2
This is where you set the magnetic declination for Rotator 2.
This value varies depending on your current geographical location. You can calculate it online
using a service such as:
It is a value to be subtracted or added to the azimuth value.
It will be subtracted if the value is negative.
It will be added if the value is positive.
Press the
Use
and
Press the
Use
button to navigate to next item.
SAVE&EXIT
When this item is selected press the
The device will return to the normal operating state.
If you made a mistake and don't want to apply changes you made either go back and modify the
values or power toggle the device.

3. Connecting and Wiring The Rotors

Rotator Genius can control five different categories of rotors:
1. Low Range DC motors - 3 to 48V, up to 15A of current.
2. Low Range AC motors - 3 to 48V, up to 15A of current.
3. High Range AC motors single phase - 110 to 220V.
4. High Range AC three phase motors - 110 to 380V.
5. Prop Pitch motors.
DIP Switches on the back of RG are used to configure the type of rotor you intend to control.
First RG series have wrong stickers if this is the case know that the DIP switches are always next to the Sensor
connectors as on the picture below.
The remaining 8 DIP switches next to the ethernet connector serve no purpose in the current version and are
reserved for future use.
Back to table of contents
http://www.ngdc.noaa.gov/geomag- web/
Select
button to edit the item.
buttons to increase or decrease its value.
Select
button when done.
Select
button to save the changes you made.
Page 5