4RF Aprisa XE Технический документ - Страница 10

Просмотреть онлайн или скачать pdf Технический документ для Сенсорные терминалы 4RF Aprisa XE. 4RF Aprisa XE 15 страниц. Radio link
Также для 4RF Aprisa XE: Краткое руководство по эксплуатации (2 страниц), Краткое руководство по эксплуатации (2 страниц)

4RF Aprisa XE Технический документ
4.

Network Clocking Examples

4.1.

Single Link

Figure 10 : Single link network diagram
The above network is the simplest network possible. One radio is set to "Internal" clocking and the other
"Link". The radio set to internal will generate an internal clock for timing. The radio set to "Link" will use the
clock extracted from data stream passed over the RF link.
Back to back links – Unframed E1
4.2.
Figure 11 : Back to back unframed E1 network diagram
The above network uses a repeater site to pass the radio traffic between three sites. At the repeater site
the radios are interlinked via Unframed E1. As clocking information is carried across this E1 circuit the
next radio pair can be set to Internal and its partner Link.
Aprisa XE Clocking Technical Paper
10 | 15
Issued by: 4RF Customer Services 15 January 2009