4.5.

Branched Network - Mixed

Figure 14 : Branched network diagram
The above network uses a repeater site to pass E1 to two sites. In this case a mix of Framed E1 and
Unframed E1 is used. As in previous examples Framed E1 needs to have external clocking used.
Unframed E1 can have Internal clocking used.
The radios linking between the Repeater site and Remote 1 have clocking set to External / Link as
Framed E1 is being carried.
The radios linking between the Repeater site and Remote 2 have clocking set to Internal / Link as Framed
E1 is being carried.
Aprisa XE Clocking Technical Paper
12 | 15
Issued by: 4RF Customer Services 15 January 2009