4RF Aprisa XE Технический документ - Страница 12
Просмотреть онлайн или скачать pdf Технический документ для Сенсорные терминалы 4RF Aprisa XE. 4RF Aprisa XE 15 страниц. Radio link
Также для 4RF Aprisa XE: Краткое руководство по эксплуатации (2 страниц), Краткое руководство по эксплуатации (2 страниц)
4.5.
Branched Network - Mixed
Figure 14 : Branched network diagram
The above network uses a repeater site to pass E1 to two sites. In this case a mix of Framed E1 and
Unframed E1 is used. As in previous examples Framed E1 needs to have external clocking used.
Unframed E1 can have Internal clocking used.
The radios linking between the Repeater site and Remote 1 have clocking set to External / Link as
Framed E1 is being carried.
The radios linking between the Repeater site and Remote 2 have clocking set to Internal / Link as Framed
E1 is being carried.
Aprisa XE Clocking Technical Paper
12 | 15
Issued by: 4RF Customer Services 15 January 2009