8
Model 485 Dispensing Valve User Guide
There are two 8-32 UNC holes on the dispense valve for mounting purposes (Figure 5).

System Interconnect

Figure 3. Valve Interconnect Diagram
Material Reservoir
(20 oz Cartridge
Reservoir Shown)
Air In
Model 485 Valve
Air
Once the dispense valve is secured to its mounting surface, connect the airline to the
port provided on the valve (Figure 3). Also connect your air supply (60-80 psi) to your
valve controller or 3-way solenoid valve (a valve controller or a 3-way solenoid valve
must be used to operate the Model 485 valve (CV of .01 or greater)). Please refer to the
valve controller user guide for detailed instructions.
Fluid
The Model 485 valve requires a material reservoir or pressure tank to draw material
from. The material reservoir should be connected to the 485 valve through the material-
in port (Figure 3) located on the valve body.
Precision Air Regulator
(Recommended)
Material In
Air Filter Regulator
with Dump Valve
(Recommended)
Valve Controller or
Solenoid Valve
(DVC-345 Shown)
Air