System Interconnect
Refer to Table 1 to determine how to plumb the particular dispensing valve you are
using with the digital controller. For Model 300, 455, 475, 775, and 826 dispensing
valves, one of the Air-Out Ports must be plugged since these dispensing valves are
single acting.
Begin set-up by attaching a 0.25" [0.64 cm] Air Line to the Air-In Fitting on the rear of
the Controller.
Next, ensure that the Power Toggle Switch is in the OFF position. Plug the cylindrical
end of the DC Wall Mount Adapter into the Power Supply Receptacle on the back of the
Controller and plug the DC Wall Adapter in an appropriate outlet.
Plug the Foot Switch into the External Trigger Receptacle on the back of the Controller.
Attach the Material Reservoir to the Dispensing Valve and the appropriate air supply
Consult Dymax if you are unsure of this step.
pressure to the Material Reservoir.
Excessive air pressure to a Reservoir can result in a dangerous or deadly situation!
The system is ready for operation.