INSTALLATION

WIRING INSTRUCTIONS:
• The appropriate power source is 220~240 volt AC single
phase supplied. When installing or removing the smoke
alarm you must turn off the AC power to ensure safety.
• Connecting wires are recommended to use a cross sectional
area from 0.8 mm2 to 1.5 mm2, or according to local wiring
standard.
• The smoke alarm device shall be connected to an ALL-
POLE MAINS SWITCH from a circuit within the household
consumer unit. The ALL-POLE MAINS SWITCH shall have a
contact separation of at least 3 mm in each pole.
• A terminal block should be used to connect the AC
QUICK CONNECTOR to the AC main power supply. The
terminalshould allow the connection of conductors having
nominal cross-sectional areas of between 0.4mm2 and 1.5
mm2. (refer to Diagram 10)
• When alarms are interconnected, all interconnected units
should be powered from a single circuit.
• A maximum of 12 Emerald Planet smoke alarms is
recommended to be interconnected in a multiple station
arrangement, over 12 devices maybe result in overload.
• Diagram 8 illustrates interconnection wiring, inappropriate
connection may result in damage to the alarm, failure to
operate, or a shock hazard.
WIRES CONNECTED TO:
• Brown wire - Live wire of AC line
• Blue wire - Neutral wire of AC line
• White wire - I/O signal as interconnect line with other
smoke alarms in a multiple station set up.
MOUNTING INSTRUCTIONS:
• After selecting the proper location for your smoke alarm,
wiring the AC QUICK CONNECTOR as described in the
Wiring instructions (AC power should be turned off at
this stage).
• Pull the AC QUICK CONNECTOR through the center hole in
the bracket.
• Remove the plastic tab from the battery enclosure.
• Connect the AC QUICK CONNECTOR to the
alarm body.
EMERALD PLANET HEAD OFFICE - SYDNEY Unit 2 / 29 Mitchell Road, Brookvale NSW 2100 Australia P 02 9466 6000
DIAGRAM 8
INTERCONNECTION WIRING
Live wire
Neutral wire
Signal wire
white
blue
First alarm
Additional alarm
DIAGRAM 9
LOCKING PLUG
DIAGRAM 10
INSTALLATION SKETCH MAP
DIAGRAM 11
brown
Additional alarm
Locking Plug