• Take care not to install the rod with iron particles, screws and other metallic substances attached
on the permanent magnets. Failure to do so can result in damage to the permanent magnets and/
or the electromagnets, or even in a failure of the pump.
���� ��
��������� �������� �����
(8) After the new diaphragm mounting blocks have been installed, install new casing blocks. The
casing blocks can be used again as new if the valves are replaced with new ones. To replace the
valves of the removed casing block with new ones, undo the five screws of casing A (Exhaust
part side) to remove casing B (Air valve side) and valve chamber cover. (Figs. 15 and 16)
Fig. 15
(9) Pull out four old valves from the casing A using radio pliers, insert each new valve into the center
hole of valve seat while paying attention to the intake and exhaust sides, and pull these valves for
firm fitting, using radio pliers or other similar means. (Figs. 17 and 18)
10
CAUTION
���
Screw
Casing Block
���� ��
Fig. 16
Valve chamber packing
Casing B
Casing A