Hidrotermal MRS-4.5 Руководство по установке и обслуживанию - Страница 9

Просмотреть онлайн или скачать pdf Руководство по установке и обслуживанию для Диспенсер для воды Hidrotermal MRS-4.5. Hidrotermal MRS-4.5 15 страниц. Residential softener

Brine valve installation and usage:
The brine valve plays two roles in the whole system: First, under the brine and slow rinse
status, with the floating ball, the brine valve can prevent the air from being inhaled which may
affect the regeneration and usability. That is, the brine valve has the function of air check.
Second, under the brine refill status. the brine valve can control the volume of refilling water by
controlling the position of floater.

9.Usage Installation

After installing the device and setting the relevant parameters, please conduct the trial
running as follows:
※ For the first use after installation, the user should add regeneration salt to the brine tank, and
water of an amount enough for a saturation, so as to make the water and salt completely mixed
as saturated solution(26%). Then the user can start the system (Only when the device is put
into for the first time, the user needs such operation.)
Resin Tank
Specitications
Water Cpacity(L)
※ Rotate the control valve to the Backwash status; slowly open the inlet valve to 1/4 position
(Avoiding to open the valve too quickly so as not to damage the device and make the resin
run off ) to slowly release the air from the resin tank; at this moment, you can hear the sound
of air-out from the drain pipeline. After the air is completely released, then open inlet valve
completely and conduct backwashing for 2~3 minutes, cleaning the impurities and broken
resin particles.
※ After the Backwash ends, rotate the hand wheel to Brine & Slow Rinse; under this status,the
salt will be absorbed from the brine tank into the resin and the resin is regenerated. After
absorbing the salt, the brine valve will close. The system will still conduct about 15 minutes
of slow rinse, wiping off the residual brine. The whole process will take about 40 minutes.
※ After the Brine & Slow Rinse ends, rotate the hand wheel to Brine Refill; the brine tank will
be refilled with water to dissolve the salt. When the level contoller reaches the required
height, the refilling will be stop. The new saturated brine will be used for next regeneration.
※ After the Brine Refill ends, rotate the hand wheel to Fast Rinse. The Fast Rinse lasts 3
minutes fast and will discharge the residual brine and compact the resin particle so as to reach
the best softening effect.
※ Take the sample outlet water to test whether it it qualified, if qualified, end Fast Rinse, and
rotate the hand wheel to Service.
Illustration: When the device is in regeneration cycle and the softened water ceases to flow
out from the outlet, then it is suggested to operate according to the reference time values. If
you want to end the step in advance, you can rotate the hand wheel to any other position.
During the trial running status, check each port. There should be no media flowing out.
Check each connection, no leakage.
0713
4
7
0717
5