Before You Call
Before you call for service, review this list. tt may save you time and expense. The list includes common occurrences that
are not the result of defective workmanship or materials in this appliance.
OCCURRENCE
Range
is not level.
Cannot move appliance easily. Appliance
must be accessible
for service.
POSSIBLE
CAUSE/SOLUTION
Poor installation.
Place
oven rack in center
of oven. Place
a level on the oven rack. Adjust
leveling
legs at base of range
until the rack is level.
When
range
is level,
cooktop
may
appear
out of alignment
if countertop
is not level.
Weak,
unstable
floor.
Be sure floor
is level and can adequately
support
range.
Contact
a carpenter
to correct
sagging
or sloping
floor.
Kitchen
cabinet
misalignment
may make
range
appear
to be unlevel.
Be sure cabinets
are square
and have sufficient
room for range
clearance.
Cabinets
not square
or are built in too tight.
Contact
a cabinet
maker
to correct
the
problem.
Contact
builder
or installer
to make
appliance
accessible.
Carpeting
interferes
with
range.
Provide
sufficient
space
so range
can
be lifted over
carpet.
Gas
line is hard-plumbed.
Have
a flexible
A.G.A./C.G.A.
approved
metal
appliance
connector
installed.
Surface
burners
do not light.
Surface
Control
knob
has not been
completely
turned
to LITE.
Push
in and turn the
Surface
Control
knob to LITE until burner
ignites
and then
turn control
knob to desired
flame
size.
Surface
burner
flame burns
halfwayaround.
Burner
ports are clogged.
With the burner
off, use a small-gauge
wire or needle
to clean
ports.
See "Surface
Burners"
in the cleaning
chart under
Care & Cleaning
for additional
cleaning
instructions.
Range
power
cord
is disconnected
from outlet
(Electric
Ignition
Models
only).
Be sure
cord
is securely
plugged
into the outlet.
Pilot
ignition
models
- is pilot lit.
Electrical
power
outage
(electric
ignition
models
only).
Burners
can be lit manually.
See
Setting
Surface
Controls.
Burner
ports
are clogged.
With the burner
off, clean ports
by using a small-gauge
wire
or needle.
Moisture
is present
after cleaning.
Lightly fan the flame
and allow burner
to operate
until
flame
is full. Dry the burners
thoroughly
following
instructions
in the Care
& Cleaning
section.
Surface
burner
flame
is orange.
Dust particles
in main
line. Allow
the burner
to operate
a few minutes
until flame
turns
blue.
Oven
does
not operate.
Entire appliance
does not operate.
In coastal
areas,
a slightly
orange
flame
is unavoidable
due to salt air.
Be sure the oven
controls
are set correctly
for the desired
function.
See Setting
Oven
Controls
or Entire
Appliance
Does Not Operate
(see
below).
Be sure
regulator
gas valve
is "ON".
See installation
instructions.
Make sure electrical
cord/plug
is plugged
tightly
into outlet
(electric
ignition
models
only).
Service
wiring
not
complete.
Contact
your
authorized
Sears
Service
Center
for
assistance.
Electrical
power
outage
(electric
ignition
models
only).
Check
house
lights
to be sure.
Call your local
electric
company
for service.
Surface
burners
can be lit manually.
See
Setting
Surface
Controls.
Be sure gas supply
is turned
on.
14