4.Operation Procedure:

5.1.Change of the setting value of Counter
How to change preset
1.
(1)
Under measuring status, press
setting value modify status , press
PS1
PS2
BA.S
continuously , select digit
LOCK
OUT1
OUT2
BA.0
CNT
TMR
RST
BA
MD
Under measuring status , press
always flickers from right to left.
(3)
PS1
Press
PS2
PS1
BA.S
PS2
BA.S
LOCK
OUT1
OUT2
BA.0
CNT
TMR
RST
BA
MD
5.2 Change the setting value of the timer
Running Mode
In the status of changing preset value, if no press any key during 60 seconds, the timer will return to Running Mode.
How to change t. OFF time from 30 sec. to 50 sec., t.ON setting from 40 sec. to 20 sec. (Output mode: FLK, Timer range: 0.1s-999
2.
(1)
Press
status of changing preset time.
PS1
Make the data
PS2
BA.S
pressing
LOCK
OUT1
OUT2
BA.0
CNT
TMR
RST
BA
MD
In timing status ,press
(3)
Press
to move the flickering
PS1
PS2
to digit "4"
BA.S
LOCK
OUT1
OUT2
BA.0
CNT
TMR
RST
BA
MD
5.Batch Counting and Batch Preset
Batch Output Action
1.
Batch counting
Batch counting value is up counting , it only can be reset by the external batch reset signal .
When batch counting value is beyond 999999 , it will reset to zero automatically , and restart to count.
Batch counting value is not affected by
value
: To change the preset value from 175 to 180.
to make it flicker
"5"
key to enter the setting value modify status , the selected digit
key to select data
"7"
t. OFF
Change preset time
key to enter the
flicker by
"3"
key twice.
to enter setting value modify status .The
key twice
Batch Reset
Batch Preset Value
0
Batch Output
RST
key or external reset signal.
Page 03
(2)
to enter
PS1
PS2
BA.S
LOCK
OUT1
OUT2
BA.0
CNT
RST
BA
MD
(4)
flickering .
PS1
PS2
PS1
PS2
BA.S
LOCK
OUT1
OUT2
BA.0
CNT
TMR
RST
BA
MD
t. ON
MD
Change delay time
(2)
Change
Pressing
PS1
PS2
t.OFF time setting then enter the
BA.S
status of changing t.ON time.
LOCK
OUT1
OUT2
BA.0
CNT
TMR
BA
MD
RST
sequence
of the
(4)
Press
"4" to "2"
PS1
Pressing
PS2
BA.S
the setting , then return to
LOCK
OUT1
OUT2
BA.0
CNT
TMR
RUN mode.
RST
BA
MD
Change
by pressing
"5" to "0"
TMR
Press
once,change
to
"7"
confirm and return to measuring status .
MD
to
"5"
by pressing
"3"
key twice.
key to complete
MD
selected
data
flickering from right to left .
key twice to change
MD
key to complete
KKCTE02T-A/0-20131221
or
5 times
,then pre
ss
to
"8"
MD
99.9s)