Starting/Stopping the Engine
Starting the Engine
NOTE: Before starting the engine, ensure you have filled the oil tank to the
correct level with oil and fuel has been added to the fuel tank.
NOTE: The oil tank is NOT filled with oil from the factory.
1. Before starting, TURN OFF the master 240Va.c switch (13) to ensure that no
electrical apparatus is electrically connected to the generator (Fig. Q/R).
2. Turn the fuel tap / lever (26) clockwise to the 'on' position (Fig. S).
3. Push the choke lever (19) forwards (towards the front of the generator) to
the full choke "START" position (Fig. T). This is not necessary if the engine is
already warm.
NOTE: The direction for the choke is also indicated below the choke lever
(19) on the air filter cover (20).
4. Press the petrol motor On/Off switch (4) to the 'On' position as indicated by
an "I" (Fig. U).
NOTE: When the engine is started for the very first time, it may require a
number of attempts to start until the fuel has travelled from the tank to the
engine. Slowly pull the recoil starter (18) to full extent 2 or 3 times to assist
an enriched fuel mixture to enter the carburettor.
5. Slowly pull the recoil starter (18) until you feel it
engage and then pull it briskly (Fig. W).
6. Once you hear the engine operating, move the
choke lever (19) backwards slowly (towards
the rear of the generator) to the "RUN" position
(Fig. T). Allow the generator to run for a few
minutes unloaded to warm up before connecting
appliances to the output of the generator.
S.
R.
ON
OFF
22
e-mail: [email protected]
MODEL: №. INF3800A • 52299
3500W Digital Inverter with Pure Sine Wave
Q.
T.
OFF
ON
RUN
START
AFTER SALES SUPPORT
1800 909 909
(toll free)
3500W Digital Inverter with Pure Sine Wave
Stopping the Engine
1. Before stopping, ensure that no electrical apparatus is electrically
connected to the generator . TURN OFF the master 240Va.c switch (13) to
turn off the power to the 3 AC sockets (12). You can also then remove any
plugs in any of the 3 AC sockets (12) on the control panel (14) (Fig Q/R).
2. Allow the petrol motor to slow down and idle for approx 30 seconds.
3. Press the On/Off switch (4) to the 'Off' position as indicated by an "O" (Fig. U).
4. Turn the fuel lever / tap (26) anti clockwise to the 'off' position (Fig. V).
Failure of the motor On/Off Switch
In the unusual event the motor On/Off switch (4) does not stop the petrol
motor of the generator, follow the following procedure to shut down the
generator:
1. Turn off the master 240Va.c switch (13) (Fig R), and remove all plugs from
the AC sockets (12) (Fig Q).
2. Ensure the On/Off switch (4) is in the "OFF" position (Fig U).
3. Move the fuel tap (26) to the OFF position (Fig V).
The generator will run for approximately 1 minute and then stop.
Do not use the generator again until the generator is serviced and the
fault corrected.
U.
V.
ON
OFF
AFTER SALES SUPPORT
1800 909 909
(toll free)
Starting/Stopping the Engine
W.
OFF
ON
e-mail: [email protected]