▣ Function
Setting method
Functions
Sensor position
Activated channel(s)
Monitoring zone width (W), height (H)
Concentrated monitoring zone
Sensitivity level
Minimum size of the scanning target
Monitoring time
Output
Teaching
Password
Initialization (except password)
IP initialization
Setting value initialization (except IP)
Sensor position
- Set the actual installed laser scanner position: view (top or bottom) and installation (left, right, or center).
- When a user look at the installed laser scanner and the sensor top, set the top view or the sensor bottom, set the bottom view.
- Setting range: Left, Right, Center
Top view, Botton view
※ Factory default: Bottom view, Left installation
※ In case of left or right installation, setting value of monitoring zone width (W) and height (H) must be entered.
※ In case of center installation, monitoring zone width (W), height (H) is not changeable.
E.g.) Platform screen door (PSD)
● Bottom view, right installation
Activated channel(s)
- The laser scanner has 4 channels (Ch1, Ch2, Ch3, Ch4).
- Activate the channel(s) for obstacle detection.
※ Factory default: Ch1, Ch2, Ch3, Ch4 activated
Remote control (RMC-LS)
-
Ch1 Ch2 Ch3
Ch4
Laser scanner program (atLidar)
-
-
-
● Top view, left installation
Laser Scanner
D-9