Autopage RF-505 Руководство по эксплуатации - Страница 8

Просмотреть онлайн или скачать pdf Руководство по эксплуатации для Автомобильная сигнализация Autopage RF-505. Autopage RF-505 12 страниц. Part 1
Также для Autopage RF-505: Программирование передатчика (1 страниц)

Second Car Operation—

The transmitter for RF-505 has the capability to operate a second RF-505
alarm system. To program the transmitter to a second RF-505 follow these
steps:
1. Repeat steps 1 & 2 from transmitter programming.
2. Press the side Shift button on the transmitter of the 2
3. While the LED light on the transmitter is ON, press the
"Lock/Unlock" button on the transmitter, there will be 1 short chirp.
4. Turn the ignition OFF, there will be 3 long chirps to confirm exit of
transmitter programming mode.

Override Function—

The override function may be used if the remote transmitter is lost or
inoperative. To operate, enter the vehicle (alarm will sound), turn the
vehicles ignition to the ON position and push the valet/override switch until
the security system stops sounding. The security system is disarmed & reset.
Have your remote transmitter serviced or replaced.
Valet Function—
The Security System has a valet or stand-by mode that can be used when the
vehicle is being serviced or valet parked. To activate the valet, turn the
vehicles ignition to the "ON" position, then push and hold the valet/override
switch for 2 seconds or until the Security Systems LED turns ON solid. Turn
the vehicles ignition to the "OFF" position; your vehicle is now in valet
mode. To reactivate, repeat the above procedure noting the Security Systems
LED will now turn OFF.

ALARM FEATURES

8
nd
car.