Galvin Engineering 48785 Руководство по установке - Страница 2

Просмотреть онлайн или скачать pdf Руководство по установке для Сантехническая продукция Galvin Engineering 48785. Galvin Engineering 48785 4 страницы. Washing machine taps

Product Installation Guidelines
PRE-INSTALLATION -
Wall Spud
− Wall spuds must be 15BSP MI and protrude from the finished wall by no more than 15mm
Note: In some situations a male thread connection on the tap may be more suited. If so, please
contact Galvin Specialised on 1300 514 074.
INSTALLATION
IMPORTANT: Galvin Specialised products must be installed in accordance with these installation
instructions and in accordance with AS/NZS 3500, the PCA and your local regulatory requirements. Water
and/or electrical supply conditions must also comply to the applicable national and/or state standards.
Failing to comply with these provisions shall void the product warranty and may affect the performance of
the product.
1. Fit washing machine body
Fit the washing machine body assembly to the
spud and fasten with a spanner.
We recommend using thread tape or
equivalent to ensure the connection does not
leak.
DO NOT tighten the body by using the top
assembly.
© Galvin Engineering Pty Ltd
MOUNTING DETAILS
2. Fit handle
Ensure the spindle is in the closed position
then fit bonnet and handle
Secure the handle using the "C" circlip and
locking ring.
Version 1, 7 October 2022, Page 2 of 4