Corbin Russwin CL33600 Руководство по установке - Страница 9

Просмотреть онлайн или скачать pdf Руководство по установке для Замки Corbin Russwin CL33600. Corbin Russwin CL33600 16 страниц. Access 600 tcrne1 series cylindrical lockset

CL33600 Series Cylindrical Lock
9.
Installing Outside (Reader) Escutcheon and Ground Wire:
a. Insert reader assembly and route wires through door (Fig. 9a).
b. Install two #8-32 x 1-3/4" flat head screws (Fig. 9b).
c. Connect pin-5 green/yellow ground wire ring terminal to top
right screw (Fig. 9c).
Fig. 9a
10.
Secure Mounting Plate using two #8 x 3/4" combination
surface mount screws.
Add Gasket (if necessary):
Remember an inside gasket must be used
when installing in an outdoor application.
Copyright © 2009 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.
5) Installation Instructions (Continued)
9
Fig. 9c Detail
Ground Wire
Ring Terminal
Fig. 9a
Fig. 9b
Inside Face of Door
Gasket required
for exterior door
applications.
Fig. 9