6. Physical Dimensions
34mm
7. Installation
7.1 Site Considerations
It is important that the beams/ photocells are mounted on
surfaces that are reasonably parallel to one another. Small
differences in the angle between the opposing parallel
surfaces can lead to large offsets in alignment between
the transmitter and the receiver - the greater the distance
that the infrared beam travels between the transmitter
and the receiver, the larger the offset.
The transmitter and receiver are typically mounted
directly opposite one another, but some leeway is given
in the form of a wide beam being cast should absolute
alignment not be possible.
CENTSYS recommends a height of 750mm, but
the height of the beam must be tailored to suit
the specific requirements of the installation.
7.2 Removing the Cover and Preparing for Mounting
Lift the front cover off by leveraging it up from the bottom
of the Photon SMART as illustrated.
50mm
FIGURE 1
FIGURE 2