Major tech MT1887 Руководство пользователя - Страница 11
Просмотреть онлайн или скачать pdf Руководство пользователя для Мультиметр Major tech MT1887. Major tech MT1887 17 страниц. True rms industrial multimeter
DISPLAY BACKLIGHT
Press the HOLD/
the back light will flash a bright blue.
The backlight will automatically turn off after 10 seconds.
HOLD
The hold function freezes the reading in the display. Press the HOLD key momentarily to
activate or to exit the HOLD function.
PEAK HOLD
The Peak Hold function captures the peak AC or DC voltage or current. The meter can capture
negative or positive peaks as fast as 1 millisecond in duration. Momentarily press the PEAK
button, "PEAK" and "MAX" will display. The meter will update the dispay each time a higher
positive peak occurs. Press the PEAK button again, "MIN" will display. The meter will update
the dispay each time a lower negative peak occurs. Press and hold the PEAK button for more
than 1 second to exit PEAK Hold mode. Auto Power Off feature will be disabled automatically
in this mode.
LOW BATTERY INDICATION
With a fresh battery installed, the battery icon
lower right corner of the LCD. The lines will disappear as the battery is used. When the
appears alone in the display, the battery should be replaced.
AUTO POWER OFF
The auto off feature will turn the meter off after 15 minutes. To disable the auto power off
feature, hold down the MODE button and turn the meter on. "APO d" will appear in the display.
Turn the meter off and then on again to re-enable the auto power off feature.
key for >1 second to turn the backlight on.
with four lines above it will be displayed in the
icon