Avantco 194CDIM50 Руководство пользователя - Страница 2

Просмотреть онлайн или скачать pdf Руководство пользователя для Льдогенератор Avantco 194CDIM50. Avantco 194CDIM50 2 страницы. Countertop dry ice machine

Avantco 194CDIM50 Руководство пользователя
User Manual
Warning and Safety
WARNING: This product works with liquid CO2 only, do not use other compressed gas cylinders with high pressure
or non-liquid CO2. A liquid CO2 cylinder with siphon tube is recommended for effective delivery of liquid CO2. A
non-liquid CO2 cylinder may be used if the tank is inverted (turned upside down). Install this product in a well-venti-
lated area to assist in venting excess CO2.
WARNING: Dry Ice can cause burns or other injuries if not properly handled. Always use PPE such as gloves while
handling dry ice.
Set-up & Operation:
NOTE: Do not use the dry ice machine when any part of it is wet
1.
Place unit on level surface, that is a comfortable work height for operator
2.
Place steel wire for connection hose around the CO2 tank
3.
Add rubber seal rings to inside of connection hose nut, then connect to CO2 tank
4.
Tighten using hands, then use a wrench to tighten it.
NOTE: do not overtighten
5.
Plug unit into appropriate 120V 5-15 outlet.
6.
Screw ice tube into the unit
7.
Slowly open CO2 tank, ensuring no leaks in the system, then fully open CO2 tank
8.
Press and release the red power button to turn the unit on
9.
Press and release the blue operation button to start the dry ice production
NOTE: Do not press the blue button without the ice tube fully engaged
10.
After approximately 2-3 minutes, the dry ice will be formed in the ice tube
11.
Using gloves, unscrew the ice tube and remove the dry ice from the tube using gravity
12.
At business close, turn the unit off and close the CO2 tank
Replacing CO2 Cylinder:
When the machine does not make a complete dry ice block, this is an indication that it is time to change the cylinder.
1.
Close the shut-off valve of the CO2 cylinder
2.
Press the blue operation button until all excess pressure is released
3.
Loosen the nut on the CO2 cylinder and remove the CO2 cylinder
4.
Replace with full CO2 cylinder
5.
Place steel wire for connection hose around the CO2 tank
6.
Add rubber seal rings to inside of connection hose nut, then connect to CO2 tank
7.
Tighten using hands, then use a wrench to tighten it.
NOTE: do not overtighten
8.
Slowly open CO2 tank, ensuring no leaks in the system, then fully open CO2 tank
9.
Press the blue operation button to ensure functionality
Troubleshooting:
Issue
Not producing a full block of dry ice
Dry Ice is not dense or full
Not producing dry ice at all
Remedy
Replace the CO2 tank with a full tank
Replace the CO2 tank with a full tank
Confirm unit is plugged in to appropriate outlet and breaker is not tripped
- 2 -