IMPORTANT NOTES
1. On the remote control switches' head there are 20 screws. In order to avoid
any bad functioning ALL THE SCREWS OF THE REMOTE CONTROL
SWITCHES MUST BE TIGHTENED (the same must be done for the
terminals' screws).
2. IT IS ABSOLUTELY FORBIDDEN TO MECHANICALLY ACTIVATE THE
REMOTE CONTROL SWITCHES BY PUSHING THE ORANGE BUTTON
3. KEEP THIS INSTRUCTIONS' SHEET.
3. POWER SUPPLY
230 Vac = L1 L3
MOTOR = D S PC
4. BOOSTER CAPACITOR
The booster capacitor must be connected to the BOOSTER terminal on the upper part of the
electronic card. It is not necessary to respect the polarity.
5. SAFETY FUSE
Inside the control unit there is a fuse engaged for the protection of both the inputs and the
24 Vac power line from short circuits and/or overloads. If damaged, the fuse "FUSE2" must be
replaced with a new 2,5 A fuse.
Control unit for single phase motors
D S
PC
230V - 50Hz
L1
L3
EN