Electrical
requirements
Before you
start...
Injury Hazard
To eliminate
the risk of burns or fire,
avoid installing
cabinet storage above
the cooking
surface.
If cabinets
are
already installed,
avoid the use of
cabinets
while cooktop
is in use.
Reaching
over a heated cooking
surface could result in a serious
burn.
Use two or more people to move and
install downdraft
vent.
Failure to follow these instructions
can
result in back or other injury.
Important:
Observe all governing
codes
and ordinances.
Proper installation
is your responsibility.
Make sure you have everything
necessary
for correct installation.
It is the responsibility
of the installer to comply with the installation
clearances specified on the model/serial
rating plate. The model/serial
rating plate is
located on the front of the downdraft vent
above the wiring box cover.
Check location
where downdraft vent will
be installed. The location should be away
from strong draft areas, such as windows,
doors and strong heating vents or fans.
Before making countertop cutout, check that
downdraft vent and cooktop location will
clear cabinet walls, backsplash, and rear
wall studs inside cabinet.
ALL OPENINGS
IN THE WALL OR
FLOOR WHERE RETRACTABLE
DOWNDRAFT
VENT IS TO BE
INSTALLED
MUST BE SEALED.
Electrical
ground
is required. See
"Electrical requirements,"
Panel B.
When installing retractable downdraft vent,
the cabinet drawer will need to be removed
and the drawer front installed permanently
to cabinet.
30" min. base cabinet
is required. If
cabinet has a drawer, 3-l/2" depth
clearance from the countertop to the top of
the drawer (or other obstruction
in the base
cabinet) is required.
Note: Downdraft vent is installed directly
behind the cooktop. Install downdraft vent
first.
Downdraft
vent is not approved
for use
in mobile homes.
Cabinet construction:
Downdraft vent is
designed for use in a cabinet with a depth of
24". The maximum depth of the overhead
cabinet is 13". Overhead cabinets installed
at either side of the downdraft vent must be
18" above the cooking surface. See cook-top
Installation
Instructions for the minimum
distance between the front edge of the
countertop and front edge of cooktop. The
minimum horizontal distance between the
overhead cabinets is the same as the width
of the installed downdraft vent.
When installing a 36" retractable downdraft
vent with three "Create-A-Cook-top"
modules, the optional support must be
installed on the front of the downdraft vent.
See installation steps for details.
Electrical Shock Hazard
Electrically
ground downdraft
vent.
Failure to follow this instruction
could
result in death, fire or electrical
shock.
L
If codes permit and a separate
grounding
wire is used, it is recommended
that a
qualified
electrician
determine
that the
grounding
path is adequate.
Do Not ground to a gas pipe.
Check with a qualified
electrician
if you are
not sure the downdraft
vent is properly
grounded.
Do Not have a fuse in the neutral or
grounding
circuit.
IMPORTANT:
Save Installation
Instructions
for electrical
inspector's
use.
Electrical
Shock Hazard
Check for electrical
wires that may be
concealed
behind wall covering
before
drilling
holes into wall.
Do not use downdraft
vent solid state
fan speed control
device.
Failure to follow these instructions
could result in death, fire or electrical
Lshock.
It is the customer's
responsibility:
To contact
a qualified
electrical
installer.
To assure that electrical
installation
is
adequate
and in conformance
with
National
Electrical
Code, ANSVNFPA
70 - latest edition*,
and local codes
and ordinances.
IA.I
A 120.volt, 60.Hz, AC-only
electrical supply is required on a
separate 15ampere
circuit, fused on both
sides of the line. A time-delay fuse or circuit
breaker is recommended.
The fuse must be
sized per local codes in accordance with the
electrical rating of the downdraft vent as
specified on the model/serial
rating plate
located on the front of the downdraft vent
above the wiring box cover.
Tools needed for
installation:
8mm
or power
318" nut
supply
driver or
cable
ratchet
le(
THE RETRACTABLE
n
DOWNDRAFT
VENT MUST BE
CONNECTED
WITH COPPER WIRE ONLY
Ic
. Wire sizes must conform to the
requirements
of the National
Electrical Code, ANSIINFPA
70 -
latest
edition*, and all local codes and
ordinances.
Wire size and connections
must
conform with the rating of the downdraft
vent.
Copies of the standard listed above may be
obtained from:
* National
Fire Protection
Association
Batterymarch
Park
Quincy,
Massachusetts
02269
sabe
Phillips
y
screwdriver
mIm.-YIaYI
screwdriv
_.
WARNING -TO
REDUCE THE RISK OF
FIRE, ELECTRIC SHOCK, OR INJURY TO
PERSONS, OBSERVE THE FOLLOWING:
A. Installation
Work And Electrical
Wiring Must Be Done By Qualified
Person(s) In Accordance
With All
Applicable
Codes And Standards,
Including
Fire-Rated Construction.
B. The combustion
airflow needed for
safe operation
of fuel-burning
equipment
may be affected by this
unit's operation.
Follow the heating
equipment
manufacturer's
guideline
and safety standards
such as those
published
by the National Fire
Protection
Association
(NFPA), and
the American Society for Heating,
Refrigeration
and Air Conditioning
Engineers
(ASHRAE), and the local
code authorities.
C. When cutting or drilling
into wall or
ceiling, do not damage electrical
wiring and other hidden utilities.
D. Ducted fans must always be vented to
the outdoors.
E. If this unit is to be installed
over a tub
or shower, it must be marked as
appropriate
for the application.
(DI
This downdraft vent should be
.
connected directly to the fused
disconnect
(or circuit breaker) through
flexible, armored or non-metallic
sheathed,
copper cable. Allow some slack in the cable
so the downdraft vent can be moved if
servicing is ever necessary.
IEl
~ A U.L.-listed, l/2" conduit
connector must be provided at
each end of the power supply cable (at the
downdraft vent and at the junction box).
IFI
.
A wiring diagram is located on the
downdraft vent base above the
wiring box cover.
'arts supplied
'or installation:
Electrical
connection
1. Cut a 1 -l/2" hole in floor or side of
cabinet for power supply wire. The hole
cut for electrical wiring through a wood
cabinet should be sanded until smooth.
A grommet (Part No. 302797) must cover
the hole cut for the electrical wiring
through a metal cabinet.
2. Run flexible armored or nonmetallic
sheathed copper cable from fused
disconnect circuit breaker or junction box
through the cabinet hole to the downdraft
vent location.
3. See installation
steps to connect power
supply cable to downdraft vent.
l
2 end caps
l
2 lower support
legs
l
2 overcounter
mounting
brackets
l
2 undercounter
mounting
brackets
l
1 bag of fasteners
l
1 metal cover
l
1 backdraft
damper
l
literature
package
l
optional
support
and
two screws
(36"
models only)
Parts needed
for installation:
Fire Hazard
Do Not obstruct
the flow of
combustion
and ventilation
air.
Failure to follow this instruction
could
result in fire.
l
2 conduit
connectors
l
1 wall cap for interior-mounted
motor
l
ductwork
Panel B