Alivida Sauna Controller Руководство по установке и эксплуатации - Страница 18
Просмотреть онлайн или скачать pdf Руководство по установке и эксплуатации для Контроллер Alivida Sauna Controller. Alivida Sauna Controller 19 страниц.
Meldingen en foutcodes
1.
Error Message Description
E1_1
Communicatie
problem between
controller and display
E2_1
Thermal protection
Temperature out of range
E2_2
from 1°C / 125°C
E3
Display defect
NESS
RGB Control not working
due to communication
problem between
controller and RGB box
Service interval
It is possible to set a service interval message, which will appear in the display after a preset number
of hours has elapsed. In the low level menu go to parameter 10. Here you can adjust the value
from 0 to 100 hours with the arrow keys to the left and to the right. It is not necessary to confirm the
value in this parameter. When the number of hours set in parameter 10 has elapsed, a spanner with
screwdriver will appear in the display. This service interval message can be reset in the low level menu.
Go to parameter 10, hold the option button for 2 seconds. You will then arrive at the submenu.
Pressing and holding the aroma button for 2 seconds resets the service interval counter.
By pressing the power button you leave the low level menu.
Possible cause
Bad connection between display and
controller
Display or controller malfunction
Controller failure
Thermal cut-out problem
Thermal cut-out position incorrect
Cable connection lost
Temperature sensor defective
Sensor cable connection broken
Overheating
Dip switch setting wrong. Cable
connection lost
Solution
Reset
Fix the error
+
Reset
Reset
Replace display
Check installation
18