Equipping rules

6.1
Equipping rules
Channel F
Channel E
Channel D
CPU 2
Figure 10: Main memory allocation
Slots DIMM 1A - 1C and 2A - 2C are assigned to CPU 1. Slots DIMM 1D - 1F
belong to CPU 2, but are only populated if CPU 2 is installed. The following
rules also apply:
– Start by populating the main memory at CPU 1.
– The arrows in the figure show the order in which the DIMM slots must be
populated.
V
CAUTION!
DIMM slots that are not fitted with a DIMM module must be fitted with
a dummy DIMM module to ensure sufficient cooling of the system.
24
DIMM 1F
DIMM 1E
DIMM 1D
DIMM 2A
Channel A
DIMM 1A
DIMM 2B
Channel B
DIMM 1B
DIMM 2C
Channel C
DIMM 1C
Options Guide
Main memory
CPU 1
BX920 S1