Replacement routines
4.2
Replacing the front panel module
Figure 8: Removing the front panel module
Ê Open the server as described in the
Ê Remove the screw at the right side of the front panel (see
page
23).
Ê Push the front panel module carefully out of the housing about one centi-
meter using a screwdriver.
Ê Pull the front panel module out of the housing.
Ê Disconnect the front panel cable from the front panel module.
Ê Connect the front panel cable to the new front panel module.
Ê Push the front panel module into the housing. Be careful not to damage the
front panel cable.
Ê Fasten the front panel board with the screw.
Ê Route the front panel cable in the cable clamps again.
Ê Close the server and connect all power plugs (for a detailed description see
the Options Guide).