Clearance Heights

The cooker hood is designed to be fitted over a cooking
appliance at the clearance heights stated, provided the
maximum output of the appliance beneath does not
exceed the maximums quoted in the Technical
Specifications.
If the output of the appliance below the cooker hood
exceeds the maximum outputs quoted, please refer to
the cooker manufacturer's installation instructions.
A minimum clearance height of 650mm (25 1/2 ins) is
required when installed above a built-in electric hob, or
700mm (27 1/2 ins) when installed above a built-in gas
hob.
A minimum clearance height of 685mm (27 ins) is
required when installed above a slot-in electric oven, or
787mm (30 1/2 ins) when installed above a slot-in gas
oven.
When installed between adjoining wall cabinets, the wall
cabinets must not overhang the hob and the distance
beetween the underside of the cabinet and the worktop
must be 450mm. If the height of the wall cabinet is less
than 450mm a gap of 50mm must be maintained
either side of the hob.
This cooker hood must not be installed
above a cooking appliance with a high
level grill.

Selecting the type of installation:

The extraction unit at the top of the chimney can be
installed in one of three ways.
1.
Air outlet turned upwards recirculation only (fig.
2a).
2.
Air outlet turned towards the wall -extraction only
(fig. 3).
3.
Air outlet turned left or right -extraction only (fig.
4a and 4b).
INSTALLING THE COOKER HOOD
A: Built-in Electric Hob:
B: Built-in Gas hob:
C: Slot-in Electric Cooker: 685mm minimum clearance
D: Slot-in Gas Cooker:
G
2a
W
12
Hob
650mm minimum clearance
700mm minimum clearance
787mm minimum clearance
R
W
4b
R
4a