Kohler CABERNET WATER-GUARD K-3408 Руководство по установке - Страница 5

Просмотреть онлайн или скачать pdf Руководство по установке для Туалеты Kohler CABERNET WATER-GUARD K-3408. Kohler CABERNET WATER-GUARD K-3408 8 страниц. Vitreous china siphon vortex toilet

For most satisfactory operation of this toilet, 25 to 80 p.s.i.
working pressure is required at the fixture. A full 1/2" sup-
ply shut-off valve is recommended. A plastic nut is pro-
vided with the toilet and must be used to make the supply
connection to the toilet.
Water Level Adjustment: Turn on the water supply to the
toilet, and adjust the water level in the tank to the line on
the flush valve overflow tube. Turn the adjustment screw
counterclockwise to raise the water level. To lower the
water level, turn the screw clockwise. Flush the toilet and
repeat until the water level in the tank matches the line on
the flush valve overflow tube.
Bowl Water Level Adjustment: Use the trip chain to lift
the flush ball in the tank slightly to allow water to trickle into
the bowl until the water level in the bowl stops rising. This
is the seal height and should be noted for subsequent
adjustment. Flush the toilet and observe the water level in
the bowl after refill. If the water level is below seal height,
turn the seal screw clockwise. Reflush the toilet and check
the water level. Continue adjustment until water stops
entering the bowl just as the seal height is reached.
AA
112037-2-
(A)
Water
Level
Flush Ball
5
Trip Chain
Adjustment
Screw
Seal
Screw
Fig. #8
Kohler Co., Kohler, WI