Aqua Comfort Vintage Classic Series Руководство пользователя - Страница 6

Просмотреть онлайн или скачать pdf Руководство пользователя для Нагреватель для плавательного бассейна Aqua Comfort Vintage Classic Series. Aqua Comfort Vintage Classic Series 14 страниц. Heat pump pool heaters

SET UP MODE
WARNING: THE SET UP MODE IS DESIGNED AS AN ADVANCED USER'S AND INSTALLATION
MENU; THE DIRECTIONS IN THIS SECTION MUST BE FOLLOWED CAREFULLY. AN ERROR IN
PROGRAMMING MAY EFFECT THE OPERATION AND PERFORMANCE OF THE HEATER AND
MAY RESULT IN UNNECESSARY OR ERRONEOUS SERVICE CALLS.
Enter the set up mode by pressing both the UP and DOWN buttons for 5 seconds. Once in the set up mode,
you can advance from one screen to another by pressing the SELECT button. The setting within the screen
can be adjusted by pressing the UP or DOWN button. To exit the set up mode press both UP and DOWN
buttons at the same time for 5 seconds.
The following are screens in the SET UP mode:
POOL/SPA REMOTE
With this setting you can enable or disable the remote capability of switching from pool to spa mode
automatically. The use of an external water pressure switch in the spa piping is necessary. A two wire circuit
must be connected from the water pressure switch to the terminals marked REMOTE POOL/SPA on the
electronic control board. When enabled and the external water pressure switch is closed the control will
operate in spa mode, when the switch is opened the heater will operate in pool mode. The default setting is
"DISABLED".
REMOTE THERMOSTAT
With this setting you may enable or disable the remote capability. In the POOL MODE, you will have the
capability to call for heating or cooling depending in which mode the Heat/Cool switch on the heat pump is
set in. In SPA MODE you will have the capability to turn the heating on and off. Enabling the remote
thermostat and closing the "external switch" will call for heating or cooling regardless of the temperature set
point. In the case of a remote thermostat where the temperature will be regulated externally, set the SPA
temperature to 104 degrees F (40 C) and leave the heat pump controller in the SPA MODE. The heat pump
will run only when the remote calls for heating or cooling. The default setting is "DISABLED."
TIME DELAY
With this setting you can adjust the time delay for compressor turn on. When set to "0" the control is in test
mode. Test mode will exit automatically after 10 minutes or if power is turned off. Note: control will flash
"Delay" when ever the time delay applies. The default setting is "5."
SPA TIMER
With this setting you can adjust the time you spend in the spa in which heat is provided. The spa timer can
be set Continuous, Off, or for a time interval between 15 minutes and 20 hours in increments of 15 minutes.
Default setting is "CONTINUOUS."
6