Aqua Comfort Vintage Classic Series Руководство пользователя - Страница 8
Просмотреть онлайн или скачать pdf Руководство пользователя для Нагреватель для плавательного бассейна Aqua Comfort Vintage Classic Series. Aqua Comfort Vintage Classic Series 14 страниц. Heat pump pool heaters
• When user lowers the set point below 50 degrees F in one of these modes, that mode will be
turned OFF.
NOTE: AN EXTERNAL SWITCH LOCATED ON FRONT OF THE CONTROL PANEL IS
USED TO TOGGLE BETWEEN HEAT AND COOL.
POOL MODE – HEATING
When operating in pool heat mode display will show POOL – HEAT on the top line and the actual
pool water temperature on the bottom line. FOR EXAMPLE:
• To adjust the temperature set point user will press either the Up or DOWN button once. The
Display will show "POOL TEMPERATURE" on the top line and the current set point
temperature on the bottom line for 5 seconds (for example: SETPOINT 95F). Adjust the set
point by pressing either UP or DOWN until the new set point is reached for heating.
• The display will revert to "POOL – HEAT" after 5 seconds of inactivity and the new set
point will be stored in memory.
• When the water temperature falls 1 degree below the set point, the control will energize
heating mode (compressor) after the time delay has expired. The time delay is necessary to
ensure proper water pressure within the pool filter system and to avoid short-cycling the
compressor.
• During heating once the water temperature reaches the set point, compressor is turned off.
POOL MODE – COOLING
When operating in pool cool mode the display will show POOL – COOL on the top line and the
actual pool water temperature on the second line. FOR EXAMPLE:
• An external switched located on the front of the control panel is used to toggle between heat
and cool. Control will switch to cool mode by closing the switch in which case display will
show POOL – COOL on the top line and the current temperature on the bottom line.
• To adjust the temperature point user will press either the UP or DOWN button once. The
display will show "POOL TEMPERATURE" on the top line and the current set point
temperature on the bottom line for 5 seconds. Adjust the set point by pressing either UP or
DOWN until the new set point is reached for cooling.
• The display will revert to "POOL – COOL" after 5 seconds of inactivity and the new set
point will be stored in memory.
• When the temperature becomes 1 degree greater than the set point, the control will energize
cooling mode (compressor and reversing valve)) after the time delay has expired.
• During cooling once the water temperature reaches the set point, the compressor is turned
off.
POOL – HEAT
95º
POOL – COOL
8
70º