Symptom
Probable Cause
Hot water
Water Valve Coil
does not
enter tub in
Water Inlet
wash
Water
Blk or Wht wire at
main controller
Pressure Switch
No cold wa-
Water Valve Coil
ter to tub in
Water Inlet Screens
wash
Water
Blk or whit wire at
controller and main
relay PCB
Pressure Switch
Water comes
Drain Valve (open)
in but level
does not rise
Blk or whit wire at
controller
Water does
Water Valve Coil
not fl ush
Water Inlet Screens
softener
Water
compart-
ment.
Water does
Pressure Switch
not fl ush
softener
compart-
ment.
Water level
Pressure Switch
too high
Water
Drain System
drains
slowly
Suggested Remedy
Check coil continuity at terminals and replace if no continuity.
Check for 120 V power from main relay PCB
Check water inlet screens for blockage and clean if necessary
screens
Check to insure that water is turned on and operating.
Check black or white wires at Molex plug on PCB at main control-
ler and at relay PCB.
Check pressure switch continuity between terminals . If no con-
tinuity, check pressure switch hose for obstruction. If hose okay,
change pressure switch.
Check coil continuity at terminals and replace if no continuity.
Check water inlet screens for blockage and clean if necessary.
Check to insure that water is turned on and operating.
Check black or white wires at Molex plug on PCB at main control-
ler and at relay PCB.
Check pressure switch continuity between terminal contacts. If
no continuity, check pressure switch hose for obstruction. If hose
okay, change pressure switch.
Check these areas • Drain valve blockage • Drain valve motor and
gear train. If power but drain valve does not close, replace valve.
• Power to the drain valve. If no power to drain valve, check (brn/
yel) circuit for power.
Check black and white wires at molex plug on main PCB controller
and at main relay PCB
Check coil continuity at terminals and replace if no continuity.
Check water inlet screens for blockage and clean if necessary.
Check to insure that water is turned on and operating.
Check pressure switch continuity between terminals. If no
continuity, check pressure switch hose for obstruction. If
hose okay, change pressure switch.
Check for blockage in pressure switch hose. Check for
pressure switch opening circuit across terminals . Replace
switch if contacts do not open.
Check hoses and drain valve for blockage. Clean of inad-
equate size. if necessary. Check building drains for blockage
3