Appliance dimensions
(Ceiling fixing viewed from above)
1) Alternative positions for feeding
through the mains cable
2) Height range for appliance in
extraction mode (the appliance is
delivered with this height range as
standard).
3) Possible height range for appliance
in extraction mode (see "Installation").
Exhaust connection C 150 mm
22
Safety distance between hob and
cooker hood (S)
The minimum safety distances
between the top of a cooker or hob
and the bottom of the cooker hood
are as follows, unless a greater
distance is specified by the
manufacturer of your cooking
appliance:
– 600 mm above electric hobs and
cookers,
– 650 mm above an open grill or
deep fat fryer,
– 650 mm above gas hobs and
cookers.
If this cooker hood is installed above
a Miele Wok CS 1028 CombiSet
appliance, a minimum safety
distance of 760 mm must be
maintained between the burner and
the lower edge of the cooker hood.
For further advice, see "Warning and
Safety".
If the distance falls below the
recommended safety distance when
the canopy is lowered, the max. interval
it is allowed to be lowered must be
re-set during installation. See the
installation instructions for further
advice.