Installation
Extending or limiting the adjustment
range
The height range for the appliance can
be extended or limited by moving the
limit switch.
It may be necessary to do this if
– the distance between the hob and
the canopy when it is lowered is less
than the minimum safety disance
required. By moving the limit switch,
the height range for the appliance
can be limited (the canopy will not be
lowered as far).
– a greater adjustment range is
required (the canopy will be lowered
further). A maximum appliance
height of 1330 mm is possible.
^ Install the cooker hood according to
the installation instructions supplied.
^ Press the Down button to lower the
canopy. The canopy will be lowered
to its fullest extent.
^ Remove the grease filters.
^ Remove the cooker hood tower fixing
screw.
24
,
Ensure that the tower is held
securely while carrying out the
following steps. Danger of inury.
^ Push the tower upwards.
^ Now secure the tower with the screw
you removed earlier.
dai2257
dai2258
dai2259