HP StorageWorks 8/24 - SAN Switch Примечание к выпуску - Страница 23

Просмотреть онлайн или скачать pdf Примечание к выпуску для Переключатель HP StorageWorks 8/24 - SAN Switch. HP StorageWorks 8/24 - SAN Switch 30 страниц. Hp storageworks fabric os 6.1.2b release notes (5697-0351, march 2010)
Также для HP StorageWorks 8/24 - SAN Switch: Технические характеристики (20 страниц), Примечание к выпуску (29 страниц), Примечание к выпуску (32 страниц)

HP StorageWorks 8/24 - SAN Switch Примечание к выпуску
Fabric OS 6.1.0a fixes
Table 7
lists defects closed in the Fabric OS 6.1.0a firmware release.
Table 7 Fabric OS 6.1.0a closed defects
Closed defect summary
Under rare conditions, fabric mode TopTalker monitor does not display
correct flow values.
Attempting to configure port mirroring on a director with both 4-Gb
and 8-Gb blades may result in a software Verify error.
After repeatedly running bladedisable/enable on one FC8-48
blade for six hours, a DC Director panics.
FCR matrix settings may not persist after hafailover on a 4/256
SAN Director.
When disabling/enabling a port, Port Fencing disables the port be-
cause the allowable number of invalid transmission words is exceeded.
Under rare conditions, a DC Director panics during SAK IRNDUP when
the software watchdog detects an unexpected termination of the FICON
CUP daemon (ficud).
Port Based Routing with DLS ON does not immediately balance the
load when adding an ISL.
Ex_Port fails to come online after downgrading firmware from Fabric
OS 6.x to 5.3 under certain conditions.
Fastwrite performance issue with a particular FCIP ex-port configuration.
During storage failover/failback test with IP over FC, traffic stops and
fails to recover in single and dual backbone configurations.
During non-disruptive firmwaredownload, Ex_Ports may toggle,
causing traffic disruption in a 8/40 SAN Switch and 8/80 SAN
Switch.
After hareboot, "Probing failed" on F_Port messages may be seen on
the 8/8 SAN Switch, 8/24 SAN Switch, 8/40 SAN Switch or 8/80
SAN Switch.
Under rare conditions, ISL may get stuck at G_Port on the 8/8 SAN
Switch, 8/24 SAN Switch or 8/80 SAN Switch.
Launching Switch Throughput graph in Advanced Performance Monitor
for the 8/8 SAN Switch, 8/24 SAN Switch, 8/40 SAN Switch or
8/80 SAN Switch. Throughput graph will not display 8G/sec values.
On a 8/80 SAN Switch, the system status LED does not flash am-
ber/green when a power supply is faulted. The system status LED re-
mains steady green.
Solution
Fixed in Fabric OS 6.1.0a
Fixed in Fabric OS 6.1.0a
Fixed in Fabric OS 6.1.0a
Fixed in Fabric OS 6.1.0a
Fixed in Fabric OS 6.1.0a
Fixed in Fabric OS 6.1.0a
Fixed in Fabric OS 6.1.0a
Fixed in Fabric OS 6.1.0a
Fixed in Fabric OS 6.1.0a
Fixed in Fabric OS 6.1.0a
Fixed in Fabric OS 6.1.0a
Fixed in Fabric OS 6.1.0a
Fixed in Fabric OS 6.1.0a
Fixed in Fabric OS 6.1.0a
Fixed in Fabric OS 6.1.0a
HP StorageWorks Fabric OS 6.1.0h release notes
23