Epever LandStar LS101240LPLI Руководство - Страница 2
Просмотреть онлайн или скачать pdf Руководство для Контроллер Epever LandStar LS101240LPLI. Epever LandStar LS101240LPLI 2 страницы. Solar charge controller with built in led driver
Timer3
LED Rated Current Percentage
Timer4/5
LED Rated Current Percentage
Timer6
LED Rated Current Percentage
※The default value can be changed according to the user requirement.
4)Time Control
Control the load on/off time through setting real-time clock.
5) Intelligent Power Mode
When the battery voltage is lower than "Under Voltage Warning Recover Voltage (UVWR
adjustable)", the intelligent power mode is enabled; at this time, the LED current
percentage will be automatically reduced in linear with the voltage drop of battery. When
the battery voltage is lower than "Under Voltage Warning Voltage (UVW adjustable)", a
minimum LED current percentage (default 2%, adjustable) will be output. In addition, when
the battery voltage is higher than UVWR, the controller will exit the intelligent power mode.
NOTE:The load is ON when the controller power on 1seconds. After 1
seconds it will restore to set working mode.
NOTE:In the mode of Light ON/OFF and Light ON/Timer, the load is
turned on after 10Min. delay,the delay time can be set.
6. Setting Operation
There are two methods that it can realize controller work
mode and parameters through IR function:
1) IR Remote Controller—RC-10
2) Super Parameter Programmer—FC-01
This method can realize one-key setting operation which is
suitable for bulk quantity products setting or applied in the
projects.
NOTE: Please refer to the user manual of handheld
device.
7. Protection
Protection
Conditions
PV Reverse
When the battery is correct connecting, the
Polarity
PV can be reversed.
Battery Reverse
When the PV is not connecting, the battery
Polarity
can be reversed.
Battery Over
The battery voltage reaches to the OVD
Voltage
Battery Over
The battery voltage reaches to the LVD
Discharge
Battery
Temperature sensor is higher than 65℃
Overheating
Temperature sensor is less than 55℃
Temperature sensor is less than the low
Libattery Low
temperature value
Temperature
★
Temperature sensor is higher than the low
temperature value
Load current ≥2.5 times rated current
One short circuit, the output is OFF 5s;
Two short circuit, the output is OFF 10s;
Load Short
Three short circuit, the output is OFF 15s;
Circuit
Four short circuit, the output is OFF 20s;
Five short circuit, the output is OFF 25s;
Six short circuit, the output is OFF
Max. load voltage≥68V
One open circuit, the output is OFF 5s;
Two open t circuit, the output is OFF 10s;
Load Open
Three open circuit, the output is OFF 15s;
Circuit(Load over
Four open circuit, the output is OFF 20s;
voltage)
Five open circuit, the output is OFF 25s;
Six open circuit, the output is OFF 5s;
Seven open circuit, the output is OFF 5s
★ WARNING: If selecting a lithium battery, it must be set low temperature
value(LTV) according to the charging/ discharging temperature of lithium
battery; otherwise, the lithium battery will be damaged.
8. Troubleshooting
Faults
Possible reasons
Charging LED
indicator off during
PV
daytime when
array disconnection
sunshine falls on PV
modules properly
Min.9V can start up the
No LED indicator
controller.
Battery LED
indicator green Fast
Battery over voltage
Flashing
Battery
Battery LED
indicator red
over discharged
Battery Status LED
indicator red
Battery Overheating
flashing
All the LED indicator
System voltage error
flashing(battery red
BEIJING EPSOLAR TECHNOLOGY CO., LTD.
2H
0H
00:00—23:59H
50%
0%
0—100%
0H
0H
00:00—23:59H
0%
0%
0—100%
0H
2H
00:00—23:59H
0%
100%
0—100%
Status
The controller is not
damage
Stop charging
Stop discharging
Output is OFF
Output is ON
Stop charging or
discharge
Begin charging or
discharge
Output is OFF
Clear the fault:
Restart the controller
or wait for one
night-day cycle
(night time>3 hours).
Output is OFF
(Cycle to perform)
Troubleshooting
Confirm that PV and battery wire
connections are correct and tight
Measure battery voltage with
multi-meter. Min.9V can start up the
controller.
①Disconnect the solar array and
measure the battery voltage whether
is too high; ②Change the controller;
③ Change the battery
When the battery voltage is restored
to or above setpoint (low voltage
①
reconnect voltage), the load work
The controller will automatically stop
working. When the temperature is
below 50 º C, the controller will resume
to work.
Check whether the battery voltage
match with the controller working
3
Tel:+86-10-82894112 / 82894962 Website:www.epsolarpv.com/www.epever.com
indicator flashing)
①The connecting
wires are error or
virtual connection
Powering on
②Load mode is wrong
normally, the load is
③The controller does
off
not match with the LED
light.
④Output short circuit
The controller does not
match with the LED
light source. This
The dimming
product is a step-up
function is invalid
current control, If input
voltage is lower than
the rated voltage, it is
not working.
①When the battery is over discharged, the battery indicator will be red and the load will be off
all the time before the voltage is more than the Low Voltage Reconnect Voltage (LVRV). In
order to judge the system is normal or not, firstly measuring the battery voltage whether is
more than LVRV, if not, restarting the controller to detect the load whether it is normal.
WARNING: The LVRV can be set, but it must pay more attention that it
maybe damages the battery if the LVRV is too low.
9. Technical Specifications
Models
LS101240LPLI
Item
Nominal system
voltage
Rated charge current
10A
Max. PV open circuit voltage
Battery input voltage range
Max. output power
40W
Max. output Current
2.6A
Output voltage range
Load open circuit voltage
Maximum output efficiency
Output current
control accuracy
Lead-acid battery: Sealed(default)/Gel/Flooded/User
Battery Type
Lithium battery:LiFePO4/Li-NiCoMn/User
Equalization Voltage▼
Sealed:14.6V; Flooded:14.8V;User:9-17V
Boost Voltage▼
Sealed:14.4V;Gel:14.2V;Flooded:14.6V;User:9-17V
Float Voltage▼
Sealed/Gel/Flooded:13.8V;User:9-17V
Low Voltage
Sealed/Gel/Flooded:12.6V;User:9-17V
Reconnect Voltage▼
Under Voltage Warning
Sealed/Gel/Flooded:12.2V;User:9-17V
Recover Voltage▼
Under Voltage Warning
Sealed/Gel/Flooded:12.0V;User:9-17V
Voltage▼
Low Voltage Disconnect
Sealed/Gel/Flooded:11.1V;User:9-17V
Voltage▼
Boost Voltage▼
LiFePO4(4s):14.5V/Li-NiCoMn(3s):12.5V/User:9-17V
Low Voltage
LiFePO4(4s):12.8V/Li-NiCoMn(3s):10.5V/User:9-17V
Reconnect Voltage▼
Under Voltage Warning
LiFePO4(4s):12.8V/Li-NiCoMn(3s):12.2V/User:9-17V
Recover Voltage▼
Under Voltage Warning
LiFePO4(4s):12.0V/Li-NiCoMn(3s):10.5V/User:9-17V
Voltage▼
Low Voltage Disconnect
LiFePO4(4s):11.1V/Li-NiCoMn(3s):9.3V/User:9-17V
Voltage▼
Self-consumption
Charge Circuit Voltage Drop
Com. way
Com. distance of IR
Working environment
temperature
Enclosure
Overall dimension(mm)
87x58x22.8
Mounting dimension(mm)
Mounting hole size(mm)
Power cable
Net weight
0.18kg
◆The controller is not recognize system voltage and no temperature compensation
when the battery connect the lithium battery.
▼The parameters are 12V system at 25 º C, please double the values in 24V system.
10. Disclaimer
This warranty does not apply under the following conditions:
Damage from improper use or use in an unsuitable environment.
PV or load current, voltage or power exceeding the rated value of controller.
The controller is working temperature exceed the limit working environment
temperature.
User disassembly or attempted repair the controller without permission.
The controller is damaged due to natural elements such as lighting.
The controller is damaged during transportation and shipment.
Any changes without prior notice!
voltage. Please change to a suitable
battery or reset the working voltage
①Check the connecting cables
②Check the load mode and
parameter
③The voltage of LED light source is
not in the output voltage range of
controller
④Check the connecting cables and
LED light source
①Replace the LED light
②Reduce system rated voltage grade
and replace the product model
For example 24V system change to
12V system, and replace the
corresponding controller.
LS101260LPLI
LS102460LPLI
12VDC
12/24VDC◆
10A
10A
30V
50V
9~16V
9~32V
30W/12V
60W
60W/12V;120W/24V
60W/24V
4.0A
2.0A
(Max. Battery Voltage +2V)~60V
60V
96%
≤2%
≤18mA(12V);≤23mA(24V)
≤0.14V
IR
≤6m
-40℃~+55℃
IP68(1.5m,72h)
87x63x24.8
108.5x118x25.6
80
80
Φ4
2
PV/BAT:14AWG/2.5mm
PV/BAT:12AWG/4.0mm
2
LOAD: 18AWG/1.0mm
LOAD:18AWG/1.0mm
0.21kg
Version number:V1.8
4
LS2024120LPLI
20A
4.0A
100.5x76
Φ5
2
2
0.40kg