AccuLine 40-6537 Руководство по эксплуатации - Страница 6
Просмотреть онлайн или скачать pdf Руководство по эксплуатации для Лазерный уровень AccuLine 40-6537. AccuLine 40-6537 15 страниц. Auto-leveling rotating laser
Также для AccuLine 40-6537: Руководство по эксплуатации (18 страниц)
2.5 Base Assembly (AP1942)
Item JLT Part #
7.1
AP1690
ST2.9 x 10 Cross Plate Tapping
Screw
7.2
AP1985
Cover
7.3
AP1986
#10 Connecting PCB
7.4
AP1987
Bottom Seat Assembly
7.5
AP1988
Feeler Part
1.
Disassemble Cover (7-2) by removing 5 retaining screws (7-1)
2.
Remove #10 Connecting PCB (7-3) by sliding it out of the guide
slot of the Bottom Seat Assembly (7-4).
3.
Disassemble Bottom Seat Assembly (7-4) by desoldering the
wires of 2 Feeler Parts (7-5). Press out Feeler Parts as required.
3.0 Calibration
Calibration is a process that is used to correct for accuracy and/or functional errors above and beyond those stated in
published specifications. While Manual-leveling, Self-leveling, and Automatic-leveling (motor driven) devices have
different mechanisms that require calibration, there are similarities with optics that is consistent regardless of the
leveling mechanism. This section of the service manual discusses calibrations specific to the 40-6537. Each item
discussed is shown below.
3.1 Horizontal Mode Operation
3.1.1 Quantifying Accuracy Error
3.1.2 Characterize the type of error
3.1.2.1 Oblique Error
3.1.2.2 Taper Error
3.1.2.3 Wave Error
3.2 Vertical Mode Operation
3.3 Leveling Range Alarm Calibration
Prepared By: Tim Wojo
Description
Qty
5
1
1
1
2
Revision - Date: 0 – 03232009
40-6537 Service Manual
Page 6 of 15