CH10/CH20
1-3 Guide unit
No.
Parts name
•
STAGE
AB3X8SA (*1) 3 pcs.
‚
FRONT
COVER
ƒ
OUTER
AB3X12SA (*2) 3 pcs.
GUIDE
CUTB2X4SA (*3)
2 pcs.
„
WIRE
GUIDE
(2 pcs.)
...
ROLLER
NP2.5X22UO (*4)
(8 pcs.)
†
WIRE
GUIDE
(2 pcs.)
‡
INNER
CUTB2X4SA (*3)
GUIDE
2 pcs.
ˆ
BEARING
3PUK2X3SA (*5)
‰
SHAFT
6N3SA (*6)
±
WIRE
1 0
GUIDE
(2 pcs.)
C. DISASSEMBLY AND ASSEMBLY PROCEDURES
Screw
Grease
Adhesive
OT2008
OT2008
OT2008
OT2008
OT1028
OT2008
C-4
Remarks
Remove the base. ( See C-1.)
Apply grease on the fitting
surface of wire guide „ thinly.
Apply adhesive on the M2 tap
hole and the outside diameter of